A Trusted UK Supplier Of ESD Control Products Since 1986

Are Wrist Straps Necessary If All Other ESD Precautions Are Taken?

Wrist straps are not necessary if an operator is wearing two-foot grounders on a conductive grounded floor and doesn’t lift both heels/toes at the same time; like some people do when sitting down. If an operator is also wearing an ESD jacket but is not electrically connecting the jacket to either their body’s skin or ground, then the jacket is providing only partial protection.

Charges on the jacket may have nowhere to go or discharge to if the jacket is not grounded. A popular way to ground the jacket is with a coil cord either attached to a snap on the waist area of the jacket or via a wrist strap snapped to the inside cuff of an ESD jacket.

Click here to view our full range of ESD wrist straps.

ESD Wrist Strap

icon of a box

Next Day UK Delivery

On selected products if ordered before 1pm

icon of users

Dedicated Account Manager

Dedicated account manager to help your ordering process

icon of a pound symbol

Competitive Prices

Great value on premium quality products

Translate